1. Features Advantages
- High energy efficiency, over 85%
- High dynamic torque control; lower power consumption, saving over 15% in energy
- Optimized weak-field control maximizes rotational cycle efficiency across a wide speed range
2. Target Applications: Large and small home appliances; black and white home appliances
The design requirements for DC fan solutions are low power consumption and high efficiency. The following IPM module models are used in DC fan control applications:
– SYIM03M60ATA
– SYIM05M50BTD
– SYIM06G60BTD
3. Design Considerations
- Isolation of Drive Power Supply and Signals:
IPMs have integrated drive circuits, but they place extremely high demands on the quality of the external power supply and signal integrity.
- Independent Isolated Power Supplies: Each phase of the upper bridge arm must use an independent, isolated drive power supply; the lower bridge arm may share a single supply (though independent supplies are recommended for high-power applications). The drive voltage is typically 15V ± 10%; it must not exceed 20V or fall below 12V, as this may damage internal components or trigger under-voltage protection.
- Signal Immunity: Control signal lines and drive power lines should be physically isolated, and parallel routing should be avoided. PCB traces from the optocoupler output to the IPM input pins should be kept as short as possible (recommended not to exceed 3 cm) to prevent noise-induced false triggering. For high-speed switching applications, it is recommended to connect a small-capacity filter capacitor (e.g., 100 pF) in parallel with the input pins; however, the capacitance should not be too large to avoid affecting signal edges.
- Bootstrap Circuit Design (for Single-Supply Power):
If a bootstrap method is used to power the high-side driver, special attention must be paid to initial charging and voltage drop issues.
- Initial Charging: When the system powers up, the lower bridge arm must be turned on for a sufficient duration to allow the bootstrap capacitor to charge through the bootstrap resistor and diode. If PWM directly activates the high-side driver, insufficient bootstrap voltage may prevent normal operation.
- Capacitor Selection and Rated Voltage: The bootstrap capacitor must withstand a voltage close to the bus voltage. If MLCC ceramic capacitors are used, the DC bias effect must be considered (e.g., a significant drop in capacitance under a 15V bias). It is recommended to select a capacitor whose capacitance, at the actual operating voltage, still meets the calculated value with a margin of 3 to 5 times, or to use an electrolytic capacitor.
- Bootstrap Resistor and Diode: The bootstrap resistor must limit the transient charging current, and the diode must be a fast-recovery type with a voltage rating that meets the bus requirements.
- Power Circuit and PCB Layout:
High integration means that the impact of parasitic inductance in the power circuit on switching behavior is amplified, especially in SiC IPM or high-frequency applications.
- Bus Decoupling: DC bus smoothing capacitors (metal-film capacitors) must be closely connected to the P and N pins of the IPM to absorb surge voltages during switching. For SiC IPMs, since internal ceramic decoupling capacitors are not integrated, the close placement of external high-frequency decoupling capacitors is particularly critical; otherwise, extremely high di/dt values will cause severe voltage overshoot.
- Avoid Plane Overlap: Switching nodes with high dv/dt (U/V/W outputs) and the DC input plane (P/N) should not overlap on different PCB layers to prevent EMI issues caused by parasitic capacitive coupling. If overlap cannot be completely avoided, slotting or adding a shielding layer in the overlapping area is required.
- Current Sampling: The shunt resistor for the lower bridge arm should be an SMD type to reduce parasitic inductance. The trace connecting it to the ITRIP pin must be short and include an RC filter (with the capacitor placed close to the pin) to prevent noise from causing false overcurrent protection triggers.
- Thermal Design and Protection:
Heat Dissipation Path: For low-power IPMs without heat sinks (such as those in PQFN packages), heat is primarily dissipated through the PCB copper foil. Ensure there is sufficient copper area and vias beneath the power pins; a 2 oz copper thickness significantly improves output current capacity compared to 1 oz (in some scenarios, the improvement can reach 16%–23%). For modules with a heat sink installed, apply thermal grease as specified in the manual and control screw torque to ensure minimal thermal resistance.
- Protection Logic Coordination: The IPM’s FO (Fault Output) is an open-drain output and must be pulled up to the logic power supply. When overcurrent, undervoltage, or over-temperature protection is triggered, the IPM internally disables the driver; however, the controller must promptly shut down the input PWM via the FO signal—either at the hardware or software level—and execute a restart sequence to prevent repeated protection triggers that could lead to heat buildup.
- Special Considerations for SiC IPMs:
If an SiC IPM is selected, additional attention is required: its switching speed is extremely fast (high di/dt, high dv/dt), placing far higher demands on the driver IC’s common-mode transient immunity (CMTI) than silicon-based IPMs. At the same time, high switching frequencies exacerbate the driver chip’s own losses; if the driver IC and power chip are integrated on the same substrate, it is necessary to verify that the thermal design meets high-frequency derating requirements. Furthermore, while integrated decoupling capacitors reduce the main-loop inductance, they may limit the accurate measurement of phase current; in applications requiring a precise current loop, the sampling scheme must be evaluated.
4. Energy Efficiency
- Motors in household appliances (also known as “white goods”) are typically very large to accommodate variations in load torque and transients. Scalar control techniques often result in system inefficiency and operational noise.
- This, in turn, results in typical energy utilization rates hovering between 40% and 50%. By deploying digital signal controllers in the control system, designers can achieve smaller, quieter motors with energy utilization rates as high as 85%–90%. High energy efficiency requires receiving certification marks from government agencies and Energy Star ratings from the Department of Energy.
5. Power Factor Correction (PFC)
- PFC is a technology used to mitigate the adverse effects of electrical loads (which result in a power factor less than 1). In washing machines, PFC is necessary because the motor generates continuous transient and surge currents during the wash cycle.
- It is also used to boost the rectified supply voltage to as high as 300 V to 450 V, which is then used to power the three-phase inverter that ultimately controls the motor. PFC can be implemented externally using a separate integrated circuit, or it can be integrated into the digital signal controller without the need for a separate external PFC controller.
6. IEC 60730 Standard
- Home appliance manufacturers continue to introduce new, enhanced designs for automatic electronic controls that ensure the safe, reliable, and efficient operation of their equipment.
- In particular, the IEC 60730 standard addresses mechanical, electrical, and electronic aspects, as well as EMC and abnormal operation of AC equipment.